Sample File	C:\Users\Jake\Desktop\AIM Raw\14-8-7 Test Data.S80
Classifier Model	3080
DMA Model	3081
DMA Inner Radius(cm)	0.00937
DMA Outer Radius(cm)	0.01961
DMA Characteristic Length(cm)	0.44369
CPC Model	3775 High Flow
Reference Gas Viscosity (Pa*s)	1.83245e-005
Reference Mean Free Path (m)	6.73e-008
Reference Gas Temperature (K)	296.15
Reference Gas Pressure (kPa)	101.3
Channels/Decade	64
Multiple Charge Correction	TRUE
Nanoparticle Aggregate Mobility Analysis	FALSE
Diffusion Correction	TRUE
Gas Density	0.0012
Units	Concentration (DW)
Weight	Number
Sample #	30
Date	08/07/14
Start Time	15:57:49
Diameter Midpoint
 11.3	678469
 11.8	735015
 12.2	729489
 12.6	749872
 13.1	767525
 13.6	784560
 14.1	804432
 14.6	814203
 15.1	839013
 15.7	866055
 16.3	876887
 16.8	875663
 17.5	885918
 18.1	881136
 18.8	858047
 19.5	822262
 20.2	760482
 20.9	698415
 21.7	634191
 22.5	586604
 23.3	532190
 24.1	474709
 25.0	416605
 25.9	359808
 26.9	306821
 27.9	251001
 28.9	203759
 30.0	165351
 31.1	132184
 32.2	105134
 33.4	87360.1
 34.6	71518.5
 35.9	57269.2
 37.2	46949.5
 38.5	38621.2
 40.0	32239.3
 41.4	25554.8
 42.9	20954.3
 44.5	16839.5
 46.1	14811.9
 47.8	11826.8
 49.6	9393.3
 51.4	7854.55
 53.3	6223.8
 55.2	4954.03
 57.3	3975.61
 59.4	2943.44
 61.5	2273.41
 63.8	1762.22
 66.1	1381.1
 68.5	1088.41
 71.0	868.513
 73.7	789.598
 76.4	696.93
 79.1	665.128
 82.0	551.829
 85.1	473.373
 88.2	491.675
 91.4	366.215
 94.7	354.552
 98.2	338.646
101.8	258.65
105.5	234.854
109.4	210.31
113.4	175.148
117.6	145.853
121.9	164.167
126.3	144.124
131.0	106.46
135.8	87.3497
140.7	64.0538
145.9	87.2537
151.2	61.3379
156.8	61.0531
162.5	51.2443
168.5	47.4986
174.7	49.3457
181.1	39.5506
187.7	39.7489
194.6	28.6727
201.7	19.6254
209.1	44.2454
216.7	25.944
224.7	23.6512
232.9	23.497
241.4	32.8921
250.3	32.0402
259.5	21.0936
269.0	22.1081
278.8	24.3448
289.0	26.3702
299.6	21.4048
310.6	9.2152
322.0	15.1901
333.8	16.3246
346.0	13.9316
358.7	16.3395
371.8	19.1399
385.4	8.94329
399.5	9.05062
414.2	16.1358
429.4	9.39724
445.1	2.37928
461.4	2.42663
478.3	7.42808
Scan Up Time(s)	120
Retrace Time(s)	15
Down Scan First	FALSE
Scans Per Sample	1
Impactor Type(cm)	0.071
Sheath Flow(lpm)	5
Aerosol Flow(lpm)	0.5
CPC Inlet Flow(lpm)	1.5
CPC Sample Flow(lpm)	0.3
Low Voltage	10.701
High Voltage	9940.4
Lower Size(nm)	11.1397
Upper Size(nm)	486.968
Density(g/cc)	1
Title	
Status Flag	Normal Scan
td(s)	2.258
tf(s)	4.51249
D50(nm)	1084.4
Median(nm)	17.1669
Mean(nm)	18.3825
Geo. Mean(nm)	17.5858
Mode(nm)	17.4658
Geo. Std. Dev.	1.33265
Total Concentration(#/cm)	1.90697e+007
Comment	